Connect HowTo 1st always wait between typed characters (not on terminal but in software) +++ (slowly) returns to command mode Set Baudrate 57600 N 8 1 (or different if changed) Connect serial port Type AT -> Returns Ok Type ATO? Returns 1 = manual Mode, (O = O in Otto) - If Not Type ATO1 Type ATF? Returns Ok and after a whil found devices ---------- Example Init Master: Command Answer ' Comment ATL4 Ok ' Set 57600 baud ATO1 Ok ' Set manual mode ATR0 Ok ' Set master mode ATF? Ok ' Query Inquiry Results: 1 Blue1 001A-22-41EE22 2 Bleu2 001B-FA-AAD119 3 BleuPrint 0006-6F-22D4BA 4 Bully 016E-FF-AA3451 Inquiry End. 4 Device(s) Found. ---------- Example direct connect ATD=00066F22D4BA Ok ' Set a single device to connect (if needed) ATP=1234 Ok ' Set Pin ATP? 1234 Ok ' Check pin ATH0 Ok ' Hide connection ATH? 0 Ok ' Check hidden connection ATO0 Ok ' Switch to data mode and set automatical connect ATA Ok ' Init Connection ---------- Example set password Type ATP=1234 to set Pin ---------- Example End ------------ ---------- Example Init Slave ATL4 Ok ' Set 57600 baud ATL? Ok ' Check baud ATI1 List .. ' Current settings ATE0 Ok ' Local echo off ETE? 0 Ok ' Check echo ATD=000000000000 ' Set unique adress connect to if one master (hidden for others) ATD? 0000.. ' Check adress ATP=2805 Ok ' Set Pin ATP? 2805 Ok ' Check pin ATN= ESP.. Ok ' Set device name ATN? ESP.. Ok ' Check device name ATR1 Ok ' Set slave ATR? 1 ' Request Master or slave 0= slave is returned ---------- Example End ------------ ATA3 OK CONNECT '0006-XX-YYYYYY' or after 1-2 min timout fail to connect ---------- Example End ------------ ---------- Example enquires ATC? will request flow control but is ignored if no CTS/RTS lines connected ATC0 disables flow control ATI0 Version codes ATI1 current settings