Autor: Karl-Heinz Kübbeler   (kh_kuebbeler@web.de) , Jul 2020

A automatic baud rate determinattion can be selected by specifying
a BAUD_RATE below 100.

The number of bits used for the baud rate calculation and the use of an additional
check of the received character are determined with each group of ten.
The following list gives you an overview:

Area	 Bits  time limit   data check
10-19	 9	-		-
20-29	 2	-		-
30-39	 4	yes		-
40-49	 2	yes		-
50-59	 4	yes		-
60-69	 2	yes		yes
70-79	 4	yes		yes
80-89	 9	yes		yes

All settings of the baud rate with the last digit in the range 0-4 will select
a 16-Bit counter with a clock divided by factor 8 for time measurements.
The other settings with the last digit between 5 and 9 use a 16-Bit counter
at full CPU clock rate.

All automatic selected baud rates can be used with present hardware UARTs or
with a software solution for the UART.
Of course the optiboot programs with a automatic baud rate selection are
bigger than the programs with a fixed baud rate selection.
Die implementation of the software UART will nedd additional memory,
which will exxed the 512 byte limit in most cases.

The following table give you an overview about the setting options with software UART:

BAUD_RATE	No. of cycles	Resolution	Comment
last digit	delay loop pass	Time measurement

  0		  6/8		  8/CLK		Slow calculation, 8 cycles only for 9 Bit
  1		  10		  8/CLK
  2		   6		  8/CLK
  3		  16		  8/CLK		Increased number of cacles for a loop pass
  4		   8		  8/CLK		Increased number of cacles for a loop pass

  5		  10		  1/CLK		Slow calculation, 8 cycles only for 9 Bit
  5		   6		  1/CLK
  7		  10		  1/CLK
  8		   8		  1/CLK		Increased number of cacles for a loop pass
  9		  16		  1/CLK		Increased number of cacles for a loop pass

With the slow calculation for the pass count of the delay loop (last digit 0 and 5)
for the serial communication the risk is high, that the calculation is too slow to
end before the Stop-Bit has finished and the transmission of next Rx data has allready
started without preparing the receiver.
To prevent this situation, the other methods use either an accelerated subtract loop
for the devision or shift instructions if the divisor is a power of two.
The use of shift instruction for the division can be easier done with the increased
number of cycles for a loop pass (last digits 3,4,8,9).
Unfortunately, the solution with the shift commands only results in the shorter program
if no more than 2 shift operations are needed.