smartctl version 5.38 [i686-pc-linux-gnu] Copyright (C) 2002-8 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF INFORMATION SECTION === Model Family: Seagate Barracuda 7200.10 family Device Model: ST3160215A Serial Number: 6RA096QG Firmware Version: 3.AAC User Capacity: 160.041.885.696 bytes Device is: In smartctl database [for details use: -P show] ATA Version is: 7 ATA Standard is: Exact ATA specification draft version not indicated Local Time is: Sun Jun 13 10:10:16 2010 CEST SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 430) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 54) minutes. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 117 090 006 Pre-fail Always - 125517844 3 Spin_Up_Time 0x0003 098 097 000 Pre-fail Always - 0 4 Start_Stop_Count 0x0032 099 099 020 Old_age Always - 2010 5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 0 7 Seek_Error_Rate 0x000f 086 060 030 Pre-fail Always - 448327954 9 Power_On_Hours 0x0032 091 091 000 Old_age Always - 8374 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 099 099 020 Old_age Always - 2012 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0 189 High_Fly_Writes 0x003a 100 100 000 Old_age Always - 0 190 Airflow_Temperature_Cel 0x0022 060 049 045 Old_age Always - 40 (Lifetime Min/Max 19/40) 194 Temperature_Celsius 0x0022 040 051 000 Old_age Always - 40 (0 13 0 0) 195 Hardware_ECC_Recovered 0x001a 075 060 000 Old_age Always - 140632771 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x003e 200 188 000 Old_age Always - 7794 200 Multi_Zone_Error_Rate 0x0000 100 253 000 Old_age Offline - 0 202 TA_Increase_Count 0x0032 100 253 000 Old_age Always - 0 SMART Error Log Version: 1 ATA Error Count: 7406 (device log contains only the most recent five errors) CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 7406 occurred at disk power-on lifetime: 6916 hours (288 days + 4 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 00 00 00 00 f0 Error: ICRC, ABRT at LBA = 0x00000000 = 0 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 03 48 0f 3b 9c f0 00 00:02:38.065 READ DMA EXT 25 03 20 ef 3a 9c f0 00 00:02:38.055 READ DMA EXT 25 03 20 0f 3f 95 f0 00 00:02:38.051 READ DMA EXT 25 03 10 bf e1 be f0 00 00:02:38.047 READ DMA EXT 25 03 38 27 20 bf f0 00 00:02:38.030 READ DMA EXT Error 7405 occurred at disk power-on lifetime: 4899 hours (204 days + 3 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 00 00 00 00 e0 Error: ICRC, ABRT at LBA = 0x00000000 = 0 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 08 ef 0c 00 e0 00 06:12:54.695 READ DMA c8 00 01 00 00 00 e0 00 06:12:54.246 READ DMA c8 00 08 ef 0c 00 e0 00 06:12:54.245 READ DMA ec 00 00 00 00 00 a0 00 06:12:53.802 IDENTIFY DEVICE c8 00 08 ef 0c 00 e0 00 06:12:53.789 READ DMA Error 7404 occurred at disk power-on lifetime: 4899 hours (204 days + 3 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 00 00 00 00 e0 Error: ICRC, ABRT at LBA = 0x00000000 = 0 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 08 ef 0c 00 e0 00 06:12:54.695 READ DMA ec 00 00 00 00 00 a0 00 06:12:54.246 IDENTIFY DEVICE c8 00 08 ef 0c 00 e0 00 06:12:54.245 READ DMA c8 00 01 00 00 00 e0 00 06:12:53.802 READ DMA c8 00 08 ef 0c 00 e0 00 06:12:53.789 READ DMA Error 7403 occurred at disk power-on lifetime: 4899 hours (204 days + 3 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 00 00 00 00 e0 Error: ICRC, ABRT at LBA = 0x00000000 = 0 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 08 ef 0c 00 e0 00 06:12:54.695 READ DMA c8 00 01 00 00 00 e0 00 06:12:54.246 READ DMA c8 00 08 ef 0c 00 e0 00 06:12:54.245 READ DMA ec 00 00 00 00 00 a0 00 06:12:53.802 IDENTIFY DEVICE c8 00 08 ef 0c 00 e0 00 06:12:53.789 READ DMA Error 7402 occurred at disk power-on lifetime: 4899 hours (204 days + 3 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 84 51 00 00 00 00 e0 Error: ICRC, ABRT at LBA = 0x00000000 = 0 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 08 ef 0c 00 e0 00 06:12:53.212 READ DMA ec 00 00 00 00 00 a0 00 06:12:54.246 IDENTIFY DEVICE c8 00 08 ef 0c 00 e0 00 06:12:54.245 READ DMA c8 00 28 e7 7f 0b e2 00 06:12:53.802 READ DMA e1 00 00 00 00 00 a0 00 06:12:53.789 IDLE IMMEDIATE SMART Self-test log structure revision number 1 SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.