smartctl version 5.38 [i686-pc-linux-gnu] Copyright (C) 2002-8 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF INFORMATION SECTION === Model Family: SAMSUNG SpinPoint P80 SD series Device Model: SAMSUNG HD080HJ Serial Number: S08EJ1UL426109 Firmware Version: ZH100-41 User Capacity: 80.026.361.856 bytes Device is: In smartctl database [for details use: -P show] ATA Version is: 7 ATA Standard is: ATA/ATAPI-7 T13 1532D revision 4a Local Time is: Sun Jun 13 10:10:27 2010 CEST SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x02) Offline data collection activity was completed without error. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (1825) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 30) minutes. SCT capabilities: (0x003f) SCT Status supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 253 100 051 Pre-fail Always - 0 3 Spin_Up_Time 0x0007 100 100 025 Pre-fail Always - 3968 4 Start_Stop_Count 0x0032 096 096 000 Old_age Always - 4462 5 Reallocated_Sector_Ct 0x0033 253 253 010 Pre-fail Always - 0 7 Seek_Error_Rate 0x000f 253 253 051 Pre-fail Always - 0 8 Seek_Time_Performance 0x0025 253 253 015 Pre-fail Offline - 0 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 5890 10 Spin_Retry_Count 0x0033 253 253 051 Pre-fail Always - 0 11 Calibration_Retry_Count 0x0012 253 253 000 Old_age Always - 0 12 Power_Cycle_Count 0x0032 098 098 000 Old_age Always - 2379 187 Reported_Uncorrect 0x0032 253 253 000 Old_age Always - 0 190 Airflow_Temperature_Cel 0x0022 088 061 000 Old_age Always - 50 194 Temperature_Celsius 0x0022 088 061 000 Old_age Always - 50 195 Hardware_ECC_Recovered 0x001a 100 100 000 Old_age Always - 1841 196 Reallocated_Event_Count 0x0032 253 253 000 Old_age Always - 0 197 Current_Pending_Sector 0x0012 253 253 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0030 253 253 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0 200 Multi_Zone_Error_Rate 0x000a 253 100 000 Old_age Always - 0 201 Soft_Read_Error_Rate 0x000a 253 100 000 Old_age Always - 0 202 TA_Increase_Count 0x0032 253 253 000 Old_age Always - 0 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 No self-tests have been logged. [To run self-tests, use: smartctl -t] SMART Selective Self-Test Log Data Structure Revision Number (0) should be 1 SMART Selective self-test log data structure revision number 0 Warning: ATA Specification requires selective self-test log data structure revision number = 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.