Thread
Sensoren für PH-Messung: DFRobot Gravity Analog pH vs. EZO TM class embedded pH circuit
AD515 (75-300fA), LMC6001A (25fA-4pA 1.35mV, 20 EUR), LMC6482A (20fA-4pA 0.75-3.8mV 2 EUR), LPC660/LPC662/LMC6041 (2fA-100pA), TS912 (10mV, 1-300pA) MAX4239 (1pA typ/2.5uV max geringer Strom und genaue Spannung) OPA111/128/129 (40fA typ 300fA max - 20pA max 0.5-2pA), LMP7701 (typ 200fA, max 50pA bias 40fA
(75-300fA), LMC6001A (25fA-4pA 1.35mV, 20 EUR), > LMC6482A (20fA-4pA 0.75-3.8mV 2 EUR), LPC660/LPC662/LMC6041 (2fA-100pA), > TS912 (10mV, 1-300pA) MAX4239 (1pA typ/2.5uV max geringer Strom und > genaue Spannung) OPA111/128/129 (40fA typ 300fA max - 20pA max 0.5-2pA), > LMP7701 (typ 200fA, max
-
Thread
Surface Voltmeter
AD515 (75-300fA), LMC6001A (25fA-4pA 1.35mV, 20 EUR), LMC6482A (20fA-4pA 0.75-3.8mV 2 EUR), LPC660/LPC662/LMC6041 (2fA-100pA),
-
Thread
OpAmp für ph-sensor
AD515 (75-300fA), LMC6001A (25fA-4pA 1.35mV, 20 EUR), LMC6482A (20fA-4pA 0.75-3.8mV 2 EUR), LPC660/LPC662/LMC6041 (2fA-100pA), aber auch CA3140 wenn es billig sine muss.
-
Thread
Differenzverstärkerschaltung
ADC-Bereich von 5 Volt fast ganz genutzt wird. Der LMC6482 ist etwas besser geeignet als der gezeichnete LPC662. Beide gehe bis auf einige mV an die Speisespannung und habel die gleichen pins Gruß Michael