-
Datei
MPU-9150_KOMP_TEST.txt
200 $framesize = 400 Config Scl = Portb.7 Config Sda = Portb.5 Declare Sub Read_mag Dim Tmp_magx(2) As Byte Dim Tmp_magy(2) As Byte Dim Tmp_magz(2) As Byte Dim Temp As Byte Dim Magx As Integer Dim Magy As Integer Dim Magz As Integer Dim Magxx As Single Dim Magyy As Single Dim Magzz As Single Wait 4 I2cinit
in „MPU-9150 Kompass mit BASCOM auslesen“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
ATA3__10.1.1.8.6120.pdf
the device may take longer to complete commands than in the Idle mode. The time to respond could be as long as 30 s. Power consumption may be reduced from that of Idle mode. In Sleep mode the device requires a reset to be activated. The time to respond could be as long as 30 s. Sleep provides the lowest
in „Widerstand von IDE-Kabel“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
ca3140-a.pdf
many single supply applications, such output Terminal 6 is sourcing current, transistor functions as as, for example, where one input is driven below the potential 18 anemitter-followertosource currentfromtheV+ bus(Terminal 7), of Terminal 4 and the phase sense of the output signal must be via D7, R9
in „OpAmp Ausgang schwingt mit 50Hz (oder 100)“ · Analoge Elektronik und Schaltungstechnik ·
-
PDF
atmel-42330-atmel-ice_userguide.pdf
Gateway Interface is an interface for streaming data from the target device to a computer. This is meant as an aid in application debugging as well as for demonstration of features in the application running on the target device. DGI consists of multiple channels for data streaming. The Atmel-ICE supports
in „AVRISP mkII Connect Failed“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
Atmel-ICE_UserGuide.pdf
Gateway Interface is an interface for streaming data from the target device to a computer. This is meant as an aid in application debugging as well as for demonstration of features in the application running on the target device. DGI consists of multiple channels for data streaming. The Atmel-ICE supports
in „Atmel ICE Programmer und UPDI“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
slod006b.pdf
as stable op amps with minimum gain restrictions. As long as gain in the circuit you design exceeds the gain specified on the data sheet, this is economical and a safe mode of operation. 7.6 Lead Compensation
in „Einfache Verstaerkerschaltung mit OP“ · Analoge Elektronik und Schaltungstechnik ·
-
PDF
OP_Amps_for_slod006b.pdf
as stable op amps with minimum gain restrictions. As long as gain in the circuit you design exceeds the gain specified on the data sheet, this is economical and a safe mode of operation. 7.6 Lead Compensation
in „Vor- und Nachteile: Unipolare vs. Bipolare Spannungsversorgung bei OpAmps“ · Analoge Elektronik und Schaltungstechnik ·
-
Datei
SlowCam_TWO.txt
Pind.1 Endschalterlinks Alias Pind.0 Ausloeser Alias Portc.2 Beleuchtung Alias Portc.0 Dim Strecke As Single Dim Adcwert As Word Dim Wartezeit As Word Dim Fotos As Word Dim Durchlauf As Word Dim Zyklus As Word Dim Richtung As Bit Dim Anzeigewert As String * 5 Dim Anzeigewert1 As String * 5 Dim Rechnen1 As Integer Dim Rechnen2 As Integer Dim Manuell As Bit Locate 1 , 5 Lcd "Slow-Cam" Locate 2 , 6 Lcd "T W O" Beleuchtung = 1 Wait 1 Beleuchtung = 0 Wait 1 Beleuchtung = 1 Wait 1 Locate 1 , 5 Lcd "copyright
in „Atmega8 Speicher zu klein“ · Mikrocontroller und Digitale Elektronik ·
-
Datei
main_rx.c
<< EN_CRC) | (1 << CRCO) | (1 << PWR_UP) | (1 << PRIM_RX))); //_delay_ms(10); printf("CONFIG read as: 0x%02X\n\n", rfm70_R_REGISTER(CONFIG)); printf("Writing EN_AA...\n"); rfm70_W_REGISTER(EN_AA, 0x3F ); //_delay_ms(10); printf("EN_AA read as: 0x%02X\n\n", rfm70_R_REGISTER(EN_AA)); printf("Writing EN_RXADDR...\n"); rfm70_W_REGISTER(EN_RXADDR, 0x3F ); //_delay_ms(10); printf("EN_RXADDR read as: 0x%02X\n\n", rfm70_R_REGISTER(EN_RXADDR)); printf("Writing SETUP_AW...\n"); rfm70_W_REGISTER(SETUP_AW, AW_5_BYTES ); //_delay_ms(10); printf("SETUP_AW read as: 0x%02X\n\n", rfm70_R_REGISTER(SETUP_AW
in „Hat jemand Erfahrung mit dem 2,4GHz-Transceiver RFM70?“ · HF, Funk und Felder ·
-
PDF
H83003H.PDF
NMI NMI 73 VSS VSS VSS VSS 74 EXTAL EXTAL EXTAL EXTAL 75 XTAL XTAL XTAL XTAL 76 VCC VCC VCC VCC 77 AS AS AS AS 78 RD RD RD RD 79 HWR HWR HWR HWR 80 LWR LWR LWR LWR 81 MD 0 MD 0 MD 0 MD 0 82 MD 1 MD 1 MD 1 MD 1 83 MD MD MD MD 2 2 2 2 9 Table 1-2 QFP-112 Pin Assignments in Each Mode (cont) Pin Name Pin
in „H8/300 Frage (genauer H8/3003)“ · Mikrocontroller und Digitale Elektronik ·
-
Datei
LCD_2313_M50530.bas
PortB alles auf 0 Led_takt Alias Portd.2 ' 2s Takt Led_v24 Alias Portd.1 ' V24-Bus-Kommunikation Dim I As Byte ' Zählvariable Dim L As Byte ' Zählvariable Dim C As Byte ' ASCII-Wert des aktuellen Zeichens zum LCD Dim Ch As String * 2 ' Str-Wert des aktuellen Zeichens zum LCD Dim Led As Bit ' Merk-Bit für Takt-LED Dim S As Byte ' Spalte für Locate Dim Z As Byte ' Zeile für Locate Dim Ioc As Byte ' Display-Modus Dim D As Byte ' Datenbyte zum LCD Dim T As Byte ' Temp-Variable in UP "Waitdisprdy" Dim Now As Byte ' Zählvariable
in „Problem bei 8x24 Zeichen LCD an Atmega 16“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
Simple__C-based_ADCs__Part_1_.pdf
of analog and discrete digital circuitry. The increasing speed of µCs extends their use to dynamic (as in real-time) control, as control elements in feedback loops. One useful dynamic application of µCs is as ADCs. ADCs over the years have gone from complete DVMs as instruments to embedded subsystems,
in „Frage zu kapazitiven Sensoren“ · Analoge Elektronik und Schaltungstechnik ·
-
Datei
LCD_2313_M50530.bas
PortB alles auf 0 Led_takt Alias Portd.2 ' 2s Takt Led_v24 Alias Portd.1 ' V24-Bus-Kommunikation Dim I As Byte ' Zählvariable Dim L As Byte ' Zählvariable Dim C As Byte ' ASCII-Wert des aktuellen Zeichens zum LCD Dim Ch As String * 2 ' Str-Wert des aktuellen Zeichens zum LCD Dim Led As Bit ' Merk-Bit für Takt-LED Dim S As Byte ' Spalte für Locate Dim Z As Byte ' Zeile für Locate Dim Ioc As Byte ' Display-Modus Dim D As Byte ' Datenbyte zum LCD Dim T As Byte ' Temp-Variable in UP "Waitdisprdy" Dim Now As Byte ' Zählvariable
in „LCD Display 8x24 mit M50530“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
Active_Negative_Inductors.pdf
can be ble,butherewewillexaminesometraditionalap- readilyseenthatthesetwovoltagesarenotonly proaches as well as the adaptation of an ap- assymetrical about signal ground, but they are proachusedinmonolithiccircuitrythathassome also not balanced. This makesit necessary to promise. usetwoseparatetransformers
in „Richtwirkung einer Loopantenne erhöhen“ · HF, Funk und Felder ·
-
PDF
C-4001SR-5.pdf
Û I.C. COMPATIBLE Û LOW POWER CONSUMPTION Û Pb FREE PRODUCTS Û ROHS COMPLIANCE Raw Material : GaAlAs/GaAs ABSOLUTE MAXIMUM RATING : ( Ta = 25B C ) SYMBOL PARAMETER SUPER RED UNIT PD Power Dissipation Per Segment 330 mW VR Reverse Voltage Per Segment(DP) 25(5) V IAF Continuous Forward Current Per Segment
in „Frage zu 7 Segent Anzeige“ · Mikrocontroller und Digitale Elektronik ·
-
Datei
Thermometer.bas
$regfile "m8def.dat" $crystal = 4000000 Config Portd = Output Config 1wire = Portb.0 Dim Temp(9) As Byte Dim X As Byte Dim Y As Byte Dim Celsius As Integer Dim Highbyte As Integer Dim Lowbyte As Integer Dim Tmp As Byte , T As Integer , T1 As Integer Cls Do 1wreset 1wwrite &HCC 1wwrite &H44 Waitms 800
-
PDF
abel-HDL_Reference.pdf
1) A k!= B k (ak != b k) # (ak-1 != bk-1) # ... # (a 1 != b1) A k+ B k D k where: dn is evaluated as a n $ b n$ c n-1 cnis evaluated as (a n $ b n) # (a n & c n-1) # (b n & c n-) c0 is evaluated as 0 A k- B k Ak + (-B k) A k< B k ck where: cn is evaluated as (!an & (bn # cn-1) # an & bn & cn-1) != 0
in „Pal Assembler Abel 3 (Data IO)“ · PC Hard- und Software ·
-
PDF
Firmware_buglist_2.06.3.pdf
Fixed, Fixed, Fixed, Fixed, /dso/app/dsod /dso/app/dsod /dso/app/dsod /dso/app/dso /dso/app/dso 16 BUG as WD as WD as WD d as WD d as WD checking checking checking checking checking profile and profile and profile and profile and profile and dso.exe state dso.exe state dso.exe state dso.exe state dso.exe
-
PDF
33963.pdf
practical load line. All parameters, such as power sup- used with either 5V or 6V supplies and battery voltages ply range, charge current load line, trickle charge rate, as high as 4.7V (3.7V for 5V supplies). The device is and timer setting, are
in „[V] 2St Dallas DS1633 Ladechip TO220 3 Pin für“ · Markt ·
-
Bild
M5Stack LoRaWAN AS923 Modul mit Antenne
UNIT LoRaWAN AS923 M5STACK AS923 LoRaWAN AS923 PORT C UART GND 5V RXD TXD AS923 STM32WLE5 UART INTERFACE
in „Bauteile: PocketBeagle, smart aufgebaute LEDs, ESP32 mit STM32 uvam“ · Mikrocontroller und Digitale Elektronik · · Fotos
-
PDF
an_06-65.pdf
gain in the current regulatingloop, the regulation in the region of current limiting operation is not as tight as in the caseofconstant currentoperation. Thus, the current limiting portion of the locusof Figure 13does not come as close to being a vertical lineas the current operating region fora CV/CC power
in „HP 6966A Schaltplan / Manual“ · Analoge Elektronik und Schaltungstechnik ·
-
PDF
HW_manual_bf533.pdf
memory block is accessed at full processor speed. L1 scratchpad RAM, which runs at the same speed as the L1 mem- ories but is only accessible as data SRAM and cannot be configured as cache memory. External Memory External (off-chip) memory is accessed via the External Bus Interface Unit (EBIU). This
in „Blackfin ADSP-BF532 - Einstieg“ · Digitale Signalverarbeitung / DSP / Machine Learning ·
-
PDF
Dsuti.pdf
operating temperature up to 180ºC The UTI is available in a 16-pin plastic dual-in-line package (DIP) as well as a 18-lead small outline package 1. General Description (SOIC). Figure 1 shows the pin configurations of DIP and SOIC. The function of the pins is listed in Table 1 . The Universal Transducer
in „Periodenmessung mit AVR“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
Microchip_AppNote_00994a.pdf
and single-phase residential meter designs. These devices Current Transformers (CTs) is described, as well as include features specific for the International Electrotechnical Commission (IEC) requirements, such how the more accurate MCP3906 can be used as an advantage in meter design. This application note will as no-load threshold and start-up current. In addition, focus on the shunt as a current-sensing choice and the MCP3905/6 Energy Meter Reference Design contains sections for compensation relating to the
in „Strom 10A bis 300A messen mit Tiny26“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
BTA41-600B-1382474.pdf
10 -50 0 50 100 150 surge duration (s) Tmb (°C) f = 50Hz; Tmb = 105 °C Fig. 1. RMS on-state current as a function of mounting Fig. 2. RMS on-state current as a function of surge base temperature; maximum values duration; maximum values BTA41-600B All information provided in this document is subject to
in „Triac BTA41600B defekt nach durchgansprüfung“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
DS2438A.pdf
portion of each device and can singulate a specific device if many are present on the 1-Wire line as well as to indicate to the bus master how many and what types of devices are present. After a ROM function sequence has been successfully executed, the memory and control functions are accessible and
in „DS2438 auslesen“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
TI_ads809.pdf
. As a result, the signal 40MHz (i.e.: baseband), the wideband, current-feedback, op- swing out of the amplifier driving the transformer can be erational amplifier OPA685 may be used. As shown in Figure reduced
in „Projekt Signal-Auswertung mit High-Speed-ADC“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
4A-ESP8266__AT_Instruction_Set__EN_v0.40.pdf
Example at_setupCmdTest at_setupCmd Set Function Design Set configuration If at_setupCmd is registered as NULL, there will be no setup command. AT Command AT+TEST Registered Callback In Example at_exeCmdTest at_exeCmd Execute Function Design Execute an action If at_exeCmd is registered as NULL, there will
in „ESP8266 Netzwerk verbinden WDT Reset V0.9.5.2 sdk21“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
QingKeV2_Processor_Manual.PDF
priority will be executed first. Interrupt 1 priority setting, same PFIC_IPRIOR1 0xE000E401 RW function as PFIC_IPRIOR0 0x00 Interrupt 2 priority setting, same PFIC_IPRIOR2 0xE000E402 RW function as PFIC_IPRIOR0 … … … … … Interrupt 254 priority setting, PFIC_IPRIOR254 0xE000E4FE RW 0x00 same function as PFIC_IPRIOR0
in „CH32V006 und CH32V007 von WCH“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
lab11.pdf
block from entrance to exit is referred to as a link path. Let us consider an example of a state graph of a sequential network shown below. This state graph has both Mealy and Moore outputs. The output Y1 and Y2 are the Mealy outputs and so should
in „Sequential System Design Using ASM Charts“ · FPGA, VHDL & Co. ·
-
Datei
PollinSpiel_Nachbau.bas
Lcd_rs Stop Ac Stop Watchdog On Int0 Int0_isr Config Int0 = Change Enable Int0 Enable Interrupts Dim Xx As Byte Dim Tasteron As Byte Dim Tasteroff As Byte Dim State As Byte Dim Level As Byte Dim Offset As Byte Dim Sequenz As Byte Dim Punkte As Byte Dim Xon As Byte Dim Eeton As Eram Byte Dim Eemax As Eram
in „Messgeraetchen aus Pollin Spiel bauen“ · Mikrocontroller und Digitale Elektronik ·
-
Datei
MiniVersion_V01.bas.txt
**** ' Deklarationen * '**************************************************************** Dim Bytes As Word Dim Byte1 As Byte Dim Byte2 As Byte Dim I As Byte ' Zählvariable Dim Stelle0 As Word Dim Stelle1 As Word Dim Stelle2 As Word Dim Stelle3 As Word Dim Lin As Byte ' Zeilennummer Dim Col As Byte '
in „Lieber OSD LC74776, zeig mir ein Bild“ · Mikrocontroller und Digitale Elektronik ·
-
Datei
druck.bas
= Yes , Polarity = Low , Phase = 0 , Clockrate = 16 , Noss = 1 Spiinit Csb = 1 'Variablen ? Dim B As Byte , C As Byte , D As Byte , E As Byte , F As Byte , V1 As Byte , V2 As Byte Dim G As Long Dim H As Long Dim Druck As Long 'scp1000 Enalbe Pd = 0 Waitms 500 'Reset ASIC Software - muss nicht sein '
in „Code für SCP1000 Drucksensor in Bascom?“ · Mikrocontroller und Digitale Elektronik ·
-
Datei
Voltmeter_tiny24_dick_und_fett_Anode2.bas
Deklarationen $crystal = 1000000 'Interner Takt benutzt ' variablen für die display routine Dim Tempstr As String * 3 Dim Y As Byte Dim Tempbyte As Byte ' Variable für Digitansteuerung Dim Digit As Byte ' Anzeige im Ganzen Dim Anzeige As String * 3 Dim Umdreh As Byte Dim Messwert As Word Dim Messwert_mal_125 As Long Dim Neuer_messwert As Long Ddra = &B11111110 'Alles Ausgang ausser PA0 Porta = &B00000001 'Ziehwiderstand an PA0 einschalten Ddrb = &B00000111 'PB0,1,2 als Ansteuerung der Segmenttreiber Dim Stringzampel
in „7segment in bascom“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
stepper_motor_ref_design_an155.pdf
0 1 0 0 0 1 0 0 0 0x88 ω = αn + - 1 0 0 1 1 0 0 1 0x99 6 Rev. 1.0 AN155 Equation 3 Common Mistakes As demonstrated in the preceding section, the linear velocity profile is not as simple as it would first appear. The values stored in the linear velocity table must n = --αt 2 2 n closely follow the non-linear
in „Schrittmotorrampe für Konstante Beschleunigung“ · Mikrocontroller und Digitale Elektronik ·
-
Datei
Bin.bas
zy # '# # '##################################### Option Explicit Public Function BinToDez(ByVal tmp As String) As Byte Dim n As Integer For n = Len(tmp) To 1 Step -1 BinToDez = BinToDez + Mid(tmp, n, 1) * (2 ^ (Len(tmp) - n)) Next n End Function Public Function DezToBin(ByVal tmp As Byte) As String Dim n As Integer, Bit As Byte For n = 7 To 0 Step -1 Bit = tmp \ (2 ^ n) tmp = tmp - Bit * (2 ^ n) DezToBin = DezToBin & Bit Next n End Function Public Function SwapByte(ByVal tmp As String) As String tmp = Right
-
PDF
app6219.pdf
controllers. To understand the microstepping concept, consider the simplified model of the stepper motor as shown in Figure 1. As previously discussed when the two coils are energized with equal currents, the resulting magnetic vector will be at 45° and the permanent magnet of the rotor will align with that
in „Motoransteuerung (24V, 4A) mit Mikrocontroller“ · Mikrocontroller und Digitale Elektronik ·
-
Datei
stdio.h
functions come in two flavours: the standard name, where the format string is expected to be in SRAM, as well as a version with the suffix "_P" where the format string is expected to reside in the flash ROM. The macro \c PSTR (explained in \ref avr_pgmspace) becomes very handy for declaring these format
in „Problem mit FDEV_SETUP_STREAM“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
174505-da-01-en-adc_08041.pdf
many sources of error in any data converter, some of which can be adjusted out. Inherent errors, such as relative The leads of the analog inputs (Pins 6 and 7) should be kept as accuracy, cannot be eliminated, but such errors as full-scale and short as possible to minimize input noise coupling and stray
in „A/D Wandler“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
dac7621.pdf
full-scale range of 0V to 4.095V while operating on a ing current between V and ground. DD supply voltage as low as 4.75V. In addition to its ability to The DAC7621 power supply should be bypassed as shown drive resistive loads, the amplifier will remain stable while in Figure 1. The bypass capacitors should
in „Frage zu DAC“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
ADC0803_4.pdf
many sources of error in any data converter, some of which can be adjusted out. Inherent errors, such as relative The leads of the analog inputs (Pins 6 and 7) should be kept as accuracy, cannot be eliminated, but such errors as full-scale and short as possible to minimize input noise coupling and stray
in „Verständnisfrage zum ADC080x (VIN-MIN/DC-Offset)“ · Analoge Elektronik und Schaltungstechnik ·
-
PDF
max690a-max805l.pdf
below the reset count. As soon as reset is released or WDI is driven high threshold,theinternaltimerrestartsthepulse.Ifabrownout or low, the timer starts counting. It can detect pulses as condition interrupts a previously initiated
in „[V] 13St MAX692A SO8 Microprocessor Supervisory Circuits/WD (6€)“ · Markt ·
-
PDF
138720_DS.pdf
the SFR area is shown in Figure 3. parallel and serial interfaces. 7FH ADuC812 MEMORY ORGANIZATION As with all 8051-compatible devices, the ADuC812 has separate 30H address spaces for Program and Data memory as shown in Fig- 2FH ure 1. Also as shown in Figure 1, an additional 640 Bytes of Flash/EE Data
in „aduc812bs Wie programmieren?“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
Protel_99_SE_Traning_Manual_PCB_Design.pdf
thresholds Section Tracks Tracks of the width entered in the check box (or narrower) will be displayed as a single line; tracks of greater width will be displayed as an outline (when tracks are displayed in Draft Mode). Strings The number entered in this field determines which strings are displayed as text
in „Protel 99“ · Platinen ·
-
PDF
PSEUDO_RANDOM_PWM.PDF
digital the beginning of the cycle, or at comparison to the se4ected duty cycle the end. This is known as a as discussed by Hui . This shift register is clocked at the desired maximum Nathan John, Greg Verge Cypress MicroSyste4s, Inc. switching frequency, and will output a The native output of the feedback
in „pseudo zufall als pwm ersatz“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
LM2621.pdf
OUT to the FB pin. This helps reduce the peak-to- inductor with a high frequency core material, such as ferrite, peak output voltage ripple as well as improve the efficiency to reduce the core losses. To minimize radiated noise, use a of the step-up regulator, because a set hysteresis of 30mV at the FB
-
Datei
CAN18XX8.h
of the foregoing restrictions may subject the * user to criminal sanctions under applicable laws, as well as to * civil liability for the breach of the terms and conditions of this * license. * * THIS SOFTWARE IS PROVIDED IN AN AS IS CONDITION. NO WARRANTIES, * WHETHER EXPRESS, IMPLIED OR STATUTORY,
in „CAN auf PIC18F6680“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
TGS2620.pdf
from those shown as typical in this Ethanol 300ppm brochure. 0.1 0 5 10 15 20 25 Circuit Voltage (Vc) Fig. 9 - Circuit voltage dependency H=5.0) Revised 03/05 6 TECHNICAL INFORMATION FOR TGS2620 2-5 Gas response 100 Figure
in „TGS2620 Raumluftsensor -> Wie RL wählen“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
mic23050.pdf
reduce parasitic inductance it is good practice to place the output bypass capacitor as close to the inductor as possible. September 2011 9 M9999-092211-E Micrel, Inc. MIC23050 The size of the inductor depends on the requirements of Applications Information Input Capacitor the application
in „LDO und Step-Down-Converter parallel“ · Analoge Elektronik und Schaltungstechnik ·
-
PDF
mitsubishi_igbt_note_e.pdf
in operation fault. (2) In order to lower surge voltage, the wire length of drive circuit should be as short as possible and snubber capacitor is adopted. The layout must minimize the stray inductance between the driver's output stage and the IGBT. This corresponds to keeping the loop area as small as
in „E-Mobilitaet - wie sieht der Antrieb eigentlich technisch aus?“ · Fahrzeugelektronik ·