Datei
bmp180.c
_cal_t* bmp180_cal) { bmp180_cal->AC1 = bmp180_read16(BMP180_REG_AC1); bmp180_cal->AC2 = bmp180_read16(BMP180_REG_AC2); bmp180_cal->AC3 = bmp180_read16(BMP180_REG_AC3); bmp180_cal->AC4 = bmp180_read16(BMP180_REG_AC4); bmp180_cal->AC5 = bmp180_read16(BMP180_REG_AC5); bmp180_cal->AC6 = bmp180_read16(BMP180_REG_AC6); bmp180_cal->B1 = bmp180_read16(BMP180_REG_B1); bmp180_cal->B2 = bmp180_read16(BMP180_REG_B2); bmp180_cal->MB
in „BMP180 Kalibrationswerte“ · Mikrocontroller und Digitale Elektronik ·
-
Datei
BMP180.c
ifndef F_CPU #define F_CPU 8000000 #endif #include <inttypes.h> #include <util/delay.h> #include "BMP180.h" #include "i2cmaster.h" #include "uart.h" int16_t AC1, AC2, AC3, B1, B2, MB, MC, MD ; uint16_t AC4, AC5, AC6; //static long B5; uint8_t BMP180_init(void) { unsigned char ID; i2c_start(BMP180_address + I2C_WRITE); i2c_write(BMP180_ID); i2c_stop(); i2c_start(BMP180_address + I2C_READ); ID = i2c_readNak(); i2c_stop(); if(ID == 0x55) { AC1 = BMP180_read_i16(0xAA); AC2 = BMP180_read_i16(0xAC); AC3 = BMP180_read_i16(0xAE); AC4 = BMP180
in „BMP180 I2C Problem?“ · Mikrocontroller und Digitale Elektronik ·
-
Datei
BMP180.c
void) { unsigned char ID; i2c_start(BMP180_address + I2C_WRITE); i2c_write(BMP180_ID); i2c_stop(); i2c_start(BMP180_address + I2C_READ); ID = i2c_readNak(); i2c_stop(); if(ID == 0x55) { AC1 = BMP180_read_i16(0xAA); AC2 = BMP180_read_i16(0xAC); AC3 = BMP180_read_i16(0xAE); AC4 = BMP180_read_u16(0xB0); AC5 = BMP180_read_u16(0xB2); AC6 = BMP180_read_u16(0xB4); B1 = BMP180_read_i16(0xB6); B2 = BMP180_read_i16(0xB8); MB = BMP180_read_i16(0xBA); MC
in „BMP180 Problem ?“ · Mikrocontroller und Digitale Elektronik ·
-
Datei
BMP180.c
(BMP180_address + I2C_WRITE); i2c_write(BMP180_ID); i2c_stop(); i2c_start(BMP180_address + I2C_READ); ID = i2c_readNak(); i2c_stop(); if(ID == 0x55) { AC1 = BMP180_read_i16(0xAA); AC2 = BMP180_read_i16(0xAC); AC3 = BMP180_read_i16(0xAE); AC4 = BMP180_read_u16(0xB0); AC5 = BMP180_read_u16(0xB2); AC6 = BMP180_read_u16(0xB4); B1 = BMP180_read_i16(0xB6); B2 = BMP180_read_i16(0xB8); MB = BMP180_read_i16(0xBA); MC
in „BMP180 I2C Problem?“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
BST-BMP180-DS000-07.pdf
by checking that none of the words has the value 0 or 0xFFFF. Table 5: Calibration coefficients BMP180 reg adr Parameter MSB LSB AC1 0xAA 0xAB AC2 0xAC 0xAD AC3 0xAE 0xAF AC4 0xB0 0xB1 AC5 0xB2 0xB3 AC6 0xB4 0xB5 B1 0xB6 0xB7 B2 0xB8 0xB9 MB 0xBA 0xBB MC 0xBC 0xBD MD 0xBE 0xBF BST-BMP180-DS000-07 | Revision
in „Suche Projektpartner für Kalmanfilter-Implementierung“ · Digitale Signalverarbeitung / DSP / Machine Learning ·
-
Datei
main.cpp
///////////////////////////////////////////////////////////////////////////////////////// void BMP_180_EPromData_Lesen(int16_t *AC1,int16_t *AC2,int16_t *AC3,uint16_t *AC4,uint16_t *AC5,uint16_t *AC6,int16_t *B1,int16_t *B2,int16_t *MB,int16_t *MC,int16_t *MD) // Liest den Luftdrucksensor BMP_180 aus
in „I2C TWI BMP180 C#“ · Mikrocontroller und Digitale Elektronik ·
-
Datei
main.cpp
///////////////////////////////////////////////////////////////////////////////////////// void BMP_180_EPromData_Lesen(int16_t *AC1,int16_t *AC2,int16_t *AC3,uint16_t *AC4,uint16_t *AC5,uint16_t *AC6,int16_t *B1,int16_t *B2,int16_t *MB,int16_t *MC,int16_t *MD) // Liest den Luftdrucksensor BMP_180 aus
in „I2C TWI BMP180 C#“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
Toko.pdf
180+ 5(ext) 120±20% 455 RMC-2A7287HM 180+ 5(ext) 110±20% 455 RMC-312162N0 180+10(ext) 164:112 164:26 110±20% 455 RMC-402353N0 180+10(ext) 164:98 164:6 110±20% 455 RMC-402503N0 180+10(ext) 164:98 164:8 110±20% 455 RMC-452252N0 180+10(ext) 164:90 164:41 110±20% 455 RMC-502182N0 180+10(ext) 164:82 164:30 110±20% 455 RMC-502503N0 180+10(ext) 164:82 164:8 110±20% 455 ROC-15000A 180+10(ext) 176:135 176:4 60±20% 455 ROC-15001A 180+
-
PDF
Cosel_LEB100F-512.pdf
0524 ( ) ¡ EFFICIENCY LEB100F-0524 ) 82 +24V 80 ACIN100V Io=100% 78 Y C N 76 DC Output I +5V I F 74 E AC Input 72 Load factor 100% Load factor 50% 70 60 100 140 180 220 260 300 100ms/DIV 20ms/DIV INPUTVOLTAGE V ¡ INPUT HARMONIC CURRENT LEB100F-0524 ( ) ¡ INPUT HARMONIC CURRENT LEB100F-0524 ( ) 10 10 Harmonic
in „Schaltnetzteil Cosel LEB100F-512 Fehlersuche“ · Analoge Elektronik und Schaltungstechnik ·
-
Datei
Umrichter.asc.txt
180 SYMBOL voltage 1184 48 R270 WINDOW 0 60 60 Left 2 WINDOW 3 -179 -17 Left 2 WINDOW 123 -132 56 Left 2 WINDOW 39 0 0 Left 2 SYMATTR InstName V6 SYMATTR Value SINE(0 5 50 0 0 180) SYMATTR Value2 AC 1 180
in „Frequenzumrichter LTSpice“ · Analoge Elektronik und Schaltungstechnik ·
-
Datei
BMP180.c
--------------------- void BMP180_get_Calibration_data(void) { AC1 = TWIMasterReadWord(0xAA); AC2 = TWIMasterReadWord(0xAC); AC3 = TWIMasterReadWord(0xAE); AC4 = TWIMasterReadWord(0xB0); AC5 = TWIMasterReadWord(0xB2); AC6 = TWIMasterReadWord
in „Atmega88- Daten von Sensoren auf Flash abspeichern“ · Mikrocontroller und Digitale Elektronik ·
-
Datei
UmrichterRect.asc.txt
Value2 AC 1 180 SYMBOL voltage 1184 48 R270 WINDOW 0 41 39 VRight 2 WINDOW 3 86 -99 VRight 2 WINDOW 123 -132 56 Left 2 WINDOW 39 0 0 Left 2 SYMATTR InstName V6 SYMATTR Value PULSE(0 10 5m 1u 1u 4.998m 10m 4) SYMATTR
in „Frequenzumrichter LTSpice“ · Analoge Elektronik und Schaltungstechnik ·
-
PDF
MKP_B32651_658.pdf
the capacitor. dV/dt values Lead spacing 10 mm 15 mm 22.5 mm 27.5 mm 37.5 mm 52.5 mm VR VRMS V DC V AC dV/dt in V/μs 250 160 ▯ 200 120 50 36 24 400 200 ▯ 300 180 100 55 36 630 250 ▯ 400 300 150 80 50 750 350 ▯ ▯ ▯ ▯ 250 160 850 450 ▯ ▯ ▯ ▯ 340 220 1000 250 ▯ 975 600 300 ▯ ▯ 500 ▯ ▯ ▯ ▯ 400 265 1250 450
in „Schleichender Leistungsverlust an Siemens Induktionskochfeld“ · Haus & Smart Home ·
-
PDF
Thyristor_Triac_App_Note__by_Littlefuse.pdf
variable resistor) value 1 must change considerably to obtain the proper timing or Load triggering for 180º in each half-cycle. R1 3.3 k R4* Figure AN1003.14 shows a simple single-time-constant 100 AC Q 1 light dimmer (phase control) circuit, giving values for both Input R 3 R2 120 V and 240 V operation.
in „Ansteuerschaltung Thyristor und Triac“ · Analoge Elektronik und Schaltungstechnik ·
-
PDF
Littelfuse_App_Note_AN1003.pdf
variable resistor) value 1 must change considerably to obtain the proper timing or Load triggering for 180º in each half-cycle. R1 3.3 k R4* Figure AN1003.14 shows a simple single-time-constant 100 AC Q 1 light dimmer (phase control) circuit, giving values for both Input R 3 R2 120 V and 240 V operation.
in „Phasenanschnittsteuerung“ · Analoge Elektronik und Schaltungstechnik ·
-
PDF
an1003.pdf
variable resistor) value must change consider- L 1 ably to obtain the proper timing or triggering for 180° in each half- Load cycle. R 1 R * Figure AN1003.14 shows a simple single-time-constant light dim- 3.3 k 4 Q 100 mer (phase control) circuit, giving values for both 120 V and AC 1 240 V operation. Input
in „hysteresefreie Phasenanschnittsteuerung“ · Analoge Elektronik und Schaltungstechnik ·
-
PDF
307.pdf
terminal (SPNO) F 307-1AH-F-C 307-1AH-F-V 307-1AH-F-S ϬʳʳHigh power type PCB terminal 1A --------- 307H-1AC-C 307H-1AC-V 307H-1AC-S (SPNO) F 307H-1AC-F-C 307H-1AC-F-V 307H-1AC-F-S Ordering Information 307 - 1A H - - C 1 2 3 4 5 6 7 8 1. 307 -- Basic series designation 6. Blank -- Standard type 2. Blank --
in „Trotec TTK 75E Luftentfeuchter, Kompressor läuft im Off Zustand“ · Haus & Smart Home ·
-
PDF
BST-BMP180-DS000-09-2.pdf
Data sheet BMP180 Digital pressure sensor Bosch Sensortec BMP180 Data sheet Document revision 2.5 Document release date 5 April 2013 Document number BST-BMP180-DS000-09 Technical reference code(s) 0 273 300 244 Notes
in „BMP180 Luftdruck Sensor“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
MW-BIC-2200.pdf
s/230VAC at full load n AC VOLTAGE RANGE 180 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz POW ER FACTOR (Typ.) 0.98/230VAC at full load EFFICIENCY (Typ.) Note.5 90% 93% 93% 93% INPUT AC CURRENT (Typ.) 11A/230VAC INRUSH CURRENT (Typ.) COLD
in „LifePo4 mit Labornetz laden und gleichzeit entladen“ · Analoge Elektronik und Schaltungstechnik ·
-
PDF
pdf.pdf
Soldadora Inverter Manual del Propietario TIPO: TIG160S, TIG180S, TIG200S, TIG180P, TIG200P, TIG180A, TIG200 AC/DC, TIG315S, TIG315 AC/DC, TIG400 MANUAL DEL USUARIO · SERIE 0IG m Ponerse una vestimenta de protección, guantes y un man- 1 Para su seguridad E dil de
in „Stahlwerk WIG AC/DC 200 Puls: Bei AC kein Lichtbogen“ · Mechanik, Gehäuse, Werkzeug ·
-
PDF
CONTACTORS.pdf
The choice of the contactor depends on the mechanical endurance Loads are categorised into various AC ratings, (AC1, AC2, AC3 etc.) (number of operations) and on the electrical heating load and the higher the AC rating the more inductive the load becomes. i.e. resistive elements, infra-red element, convectors
in „Kontaktfestbrennen durch viele LED?“ · Haus & Smart Home ·
-
PDF
ABB_Brochure_Terra_DC_Fast_charger_oct_2021.pdf
- CE Version 480 VAC or 270 VAC +/- 10% (50 Hz or 60 Hz) - UL Version DC output power rating (max) 180 kW 120 kW AC output power rating (optional) 22 kW 22 kW DC output voltage 150-920 Vdc 150-920 Vdc Number of EV served Up to 3 (CCT, CJT models) Up to 3 (CCT, CJT models) Up to 2 (CC, CJ, JJ models)
in „Standbyverbrauch Schnelladestation.“ · Haus & Smart Home ·
-
PDF
DSP2a.pdf
Form A Panasonic Industry Co., Ltd. Electromechanical Control Business DivPanasonic Industry Co.,ASCTB180E 202305 industrial.panasonic.com/ac/e/ ʔ▯▯▯ʔ 1PXFS▯3FMBZT▯ ▯0WFS▯▯▯"▯ ▯%4▯108&3▯3&-":4 5:1&4 ▯▯5ZQF▯/P▯▯▯▯JT▯PSEFSJOH▯QBSU▯OVNCFS▯GPS▯OPO▯+BQBOFTF▯NBSLFU▯▯▯▯1BSU▯/P▯▯▯▯JT▯PSEFSJOH▯QBSU▯OVNCFS▯GPS▯+BQBOFTF
-
PDF
R2E140AL4005-DB-GER.pdf
(0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com R2E140-AL40-05 AC-Radialventilator vorwärts gekrümmt, einseitig saugend Kennlinien: Luftleistung 50 Hz Druck p f s[Pa]für Rho=1,2kg/m^3 qv[cfm] 0 20 40 60 80 100 120 140 160 180 200 220 240 260 400 1,6 1,55 380 1,5 4
-
PDF
PABST_7788-742-01_BLDC_Controller.pdf
1AD41-03 OC 11.8V - Z H201 H202 Pabst Motoren Nr. 7788-020.05 B1 B1 T201 T202 T203 T204 2 H1A H1B 4 AC180 6 H2A H2B 8 AC180 AC180 AC180 GND GND M1 W1A +B1 1 3 1 1 7 1 13 1 H1A D201 D202 D203 S204 2 -B1 AA143 AA143 AA143 AA143 W1B 3 12 7788-020.02 H1B W1A W1B W2A W2B 4 R202 R203 100R 100R C R206 C W2A
in „BLDC Motor Controller fuer Pabst Motor 7788-020.05“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
PCIM_FINAL.pdf
vAC C r1 + S N N CR C P S 1 − R PFC IC Controler S TON TOFF t TS vAC AC v AC i AC t Variety of Output Voltages and Applications Variety of utput Voltages and Applications IL L C1 L r 4:1 C2 CR 2 V=48V vAC
in „Warum werden Cùk Wandler so wenig eingesetzt?“ · Analoge Elektronik und Schaltungstechnik ·
-
PDF
IGrid-TT-10KW-15KW-Brochure.pdf
EFFICIENCY 96% 95% OFF-GRID OPERATION AC INPUT AC Start-up Voltage/Auto Restart Voltage 120 - 140 VAC per phase / 180 VAC per phase Acceptable Input Voltage Range 170 - 280 VAC per phase Maximum AC Input Current 40 A PV INPUT (DC) Maximum DC
in „cos(Φ) bei WR und induktiver Last“ · Haus & Smart Home ·
-
PDF
ZAN.pdf
Temporisé à l’appel ZAN Caractéristiques techniques ZAN Données électriques Tension d’alimentation AC absolu : 20 ... 66 V, 94 ... 264 V Puissance absorbée 3,5 VA Caractéristiques de commutation suivant EN 60947-4-1, 10/91 AC1 : 250 V/0,1 ... 5 A/1100 VA DC1 : 24 V/5 A Contacts de sortie 2 OF Matériau
in „Anleitung Pilz ZAN“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
Datenblatt_verwendeteRJ45Buchse.pdf
Kompatibel mit modularem RJ45 Stecker gemäß ANSI / TIA-1096-A und IEC 60603 • Spannungsfestigkeit ≥1500V AC RMS (2250V AC Scheitelwert) gemäß IEEE 802.3 • Spannungsfestigkeit ≥1500V AC (Scheitelwert) oder Allgemeine Bestelldaten ≥1500V DC gemäß IEC 60603 Eigenschaften und Vorteile: Typ RJ45C5 T1D 3.2E4G/Y
in „RJ45 Magnetics Teensy 4.1“ · Analoge Elektronik und Schaltungstechnik ·
-
PDF
3003E.pdf
VCC AA37 a VCC AA27 a VCC AA17 a VCC VB36 b VB26 b VB16 b AB36 b AB26 b AB16 b VC34 a VC24 a VC14 a AC34 a AC24 a AC14 a VD32 c f b VD22 c f b VD12 c f b AD32 c f b AD22 c f b AD12 c f b d g d g d g d g d g d g VE31 e VE21 e VE11 e AE31 e AE21 e AE11 e VF39 f e d c VF29 f e d c VF19 f e d c AF39 f e d
in „Suche Schaltplan Netzgerät QJ3003E“ · Analoge Elektronik und Schaltungstechnik ·
-
PDF
QJ3003E_S_netzteil.pdf
VCC AA37 a VCC AA27 a VCC AA17 a VCC VB36 b VB26 b VB16 b AB36 b AB26 b AB16 b VC34 a VC24 a VC14 a AC34 a AC24 a AC14 a VD32 c f b VD22 c f b VD12 c f b AD32 c f b AD22 c f b AD12 c f b d g d g d g d g d g d g VE31 e VE21 e VE11 e AE31 e AE21 e AE11 e VF39 f e d c VF29 f e d c VF19 f e d c AF39 f e d
in „QJE 3005E III Schaltbild“ · Analoge Elektronik und Schaltungstechnik ·
-
PDF
Sanyo_CADNICA.pdf
16 45 4-6 1.6 12.0~g5 29.5 ~~ 9 N N-50AAA 1.2 50 1.0 5 14-16 15 4-6 1.6 10.5~g5 16.0 ~~ 3.7 1/AAA N-180AAA 1.2 180 1.0 18 14-16 54 4-6 1.6 10.5~g 44.5 ~~ 10 AAA N-100AA 1.2 100 1.0 10 14-16 30 4-6 1.6 14.5~g5 17.0 ~~ 8 1/AA N-270AA 1.2 270 1.0 27 14-16 81 4-6 1.6 14.5~g5 30.0 ~~ 14 2/3AA N-500AA 1.2 550
in „Was für ein Bauteile ist das“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
80RIA.pdf
CONTROL THYRISTORS Stud Version Features Hermetic glass-metal seal 80A International standard case TO-209AC (TO-94) Typical Applications DC motor controls Controlled DC power supplies AC controllers Major Ratings and Characteristics Parameters 80RIA Unit IT(AV) 80 A @ T C 85 °C I 125 A T(RMS) I @50Hz 1900
in „Womit hohen Pulsstrom durch 1 Ohm Last jagen?“ · Analoge Elektronik und Schaltungstechnik ·
-
PDF
st110s.pdf
metal case with ceramic insulator (Glass-metal seal over 1200V) 110A International standard case TO-209AC (TO-94) Compression Bonded Encapsulation for heavy duty operations such as severe thermal cycling Typical Applications DC motor controls Controlled DC power supplies AC controllers Major Ratings and
in „Defektes Schweissgerät“ · Platinen ·
-
PDF
ST7066U.pdf
Function 0 0 0 0 1 DL N F x x N:number of line is 2/1 37 us Set F:font size is 5x11/5x8 Set CGRAM 0 0 0 1 AC5 AC4 AC3 AC2 AC1 AC0 Set CGRAM address in 37 us address address counter Set DDRAM 0 0 1 AC6 AC5 AC4 AC3 AC2 AC1 AC0 Set DDRAM address in 37 us address address counter Whether during internal Read Busy
in „LCD Zeichensatz wechseln?“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
ST7066U.pdf
Function 0 0 0 0 1 DL N F x x N:number of line is 2/1 37 us Set F:font size is 5x11/5x8 Set CGRAM 0 0 0 1 AC5 AC4 AC3 AC2 AC1 AC0 Set CGRAM address in 37 us address address counter Set DDRAM 0 0 1 AC6 AC5 AC4 AC3 AC2 AC1 AC0 Set DDRAM address in 37 us address address counter Whether during internal Read Busy
in „LCD- Das ewige Leiden“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
MOSFET.pdf
270 ––– D = 180A, VDS=0V, V GS= 10V td(on) Turn-On Delay Time ––– 52 ––– ns VDD = 65V tr Rise Time ––– 230 ––– D = 180A t Turn-Off Delay Time ––– 160 ––– R = 2.7Ω d(off) G tf Fall Time ––– 260 ––– VGS = 10V g C iss
in „LeistungsMosfet Kühlfläche als Drain-Anschluss nutzen“ · Analoge Elektronik und Schaltungstechnik ·
-
PDF
Phoenix_ELR.pdf
5 V DC Schutzbeschaltung Verpolschutz Einschaltzeit typisch < 35 ms Ausschaltzeit typisch < 40 ms AC-Ausgang Nennausgangsspannung 500 V AC ( 50 Hz , 60 Hz ) Nennausgangsspannungsbereich 42 V AC ... 550 V AC Laststrom siehe Deratingkurve 75 mA ... max. 600 mA / 180 mA ... max. 2,4 A / 1,5 A ... max.
in „Günstiges Wendeschütz gesucht“ · Analoge Elektronik und Schaltungstechnik ·
-
PDF
COMGuard.pdf
Applikation Konfiguration Anwendung Übertragungsrate OD120A5 ISDN, TK-Anlagen und -Geräte bis 2Mbps OD180A5 ADSL, ISDN bis 8Mbps OD180A1-RJ Ausgänge von ADSL-, ISDN-, und RJ45-Endgeräten bis 8Mbps Produkt Spezifikationen Elektrische Eigenschaften ComGuard Doppeladern OD180A5 OD120A5 OD180A1-RJ Einheit Betriebsspannung (DC/AC ): <180/127 <120/85 <180/127 V/V rms Betriebsstrom bei +25°C: <120 <120 <120 mA Ausgangsspannung bei 100V/s: <290 <160 <290 V Nennableitwechselstrom 50Hz1: 5 5 5 Arms r PTC : 10 10 10 W a (Schaltzeit
in „Erfahrungen mit Überspannungsschutz COM Guard“ · Mikrocontroller und Digitale Elektronik ·
-
Datei
Endprogramm.bas
Sub '---------------------------------------- Sub Qq Servorauf Rauf Ic = 110 Motorlinks Rechts Ic = 180 Motorrechts Servorunter Teil6 Runter Ic = 40 Motorlinks Teil7 Rauf Ic = 40 Motorlinks Servorauf Runter Ic = 70 Motorlinks Links Ic = 45 Motorrechts Servorunter For Ac = 1 To 60 Step 1 Rechts Ic = 1
in „Programmierung mit Bascom“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
Leistungsprintrelais_888H_17A_1UK_230VAC.pdf
Contact UL Insulation Sealed type style form system approval Flux tight Sealed type washable 1A 888-1AC-F-C 888-1AC-F-V 888-1AC-F-S F (SPNO) 888-1AH-F-C 888-1AH-F-V 888-1AH-F-S 1C 888-1CC-F-C 888-1CC-F-V 888-1CC-F-S F (SPDT) 888-1CH-F-C 888-1CH-F-V 888-1CH-F-S PCB terminal 2A 888-2AC-F-C 888-2AC-F-V 888
in „230V Relais (für uC) wird warm“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
DSS9180MDC.pdf
- dreiphasig Dimensions - three phase TYP a b c (mm) d e h (mm) l x i k (mm) m Masse (A) (mm) (mm) AC-Mo DC-Mo (mm) AC-Mo DC-Mo (mm) AC-Mo DC-Mo (kg) k DSS 9020/M AC oder DC 2 124 144 96 195x102 11,0 DSS 9032/M AC oder DC 3 406 431 388 413 DSS 9040/M AC oder DC 4 144 162 112 M5 195x124 M5 15,0 DSS 9063
in „Verständnisproblem Dreiphasentransformator“ · Analoge Elektronik und Schaltungstechnik ·
-
PDF
HORIBA_Schreibtisch_Rev1.2.pdf
2 5 R 4 M1 D3 P600-H RT3 6 1 M1 P600-H 6 4µ7/100V D7 DIN-7POLR TR1 D4 100k BU5 T1 T18535 RING-CORE180VA2S 7 C5 PIC16F628SO D6 "AUF" PJ16B6 7 3 M2 3 1 750mA - + IC2 RN2 5 2 2 8 F2 AC2 AC1 0 4 HS MSTBV41 X1 R 2 6 1 M1 T2 C4 5 , RN1 4 3 2 1 D V 100k T18535 "AB" 3 3 1 1000µ/25V C BU4 2 100µ/10V ST2 ST1
in „Höhenversllbarer Schreibtisch“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
GIC_Presentation_at_PSRC_05_14_2014.pdf
DC Flux Density Shift in Transformer Cores Flux Density vs Phase angle (20 Ampd DC) 2.2 2.0 1.8 Bm, AC 1.6 Bm, (AC+DC) 1.4 1.2 1.0 0.8 l e 0.6 T DC flux = N I / R t 0.4 DC s 0.2 e D 0.0 u -90 -60 -30 0 30 60 90 120 150 180 210 240 270 300 330 360 F -0.2 -0.4 -0.6 -0.8 -1.0 -1.2 -1.4 -1.6 -1.8 Phase Angle, Degrees © ABBGroup 2013 - Slide 4 DC causes Part – Cycle, Semi – Saturation of the core AC + DC B DC Shift AC Time I ImAC ImDC § Non – linearity of the core material limits core from fully saturating Time © ABBGroup 2013 - Slide 5 Flux density shift caused by DC B GIC ΔB dc, B m(dc+ac), Amps
-
Datei
Endprogramm.bas
Return '---------------------------------------- Qq: Servorauf Rauf Ic = 110 Motorlinks Rechts Ic = 180 Motorrechts Servorunter Teil6 Runter Ic = 40 Motorlinks Teil7 Rauf Ic = 40 Motorlinks Servorauf Runter Ic = 70 Motorlinks Links Ic = 45 Motorrechts Servorunter For Ac = 1 To 60 Step 1 Rechts Ic = 1
in „Programmierung mit Bascom“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
tl431.pdf
8 2000 367.0 367.0 38.0 TL431ACPWR TSSOP PW 8 2000 367.0 367.0 35.0 TL431AIDBVR SOT-23 DBV 5 3000 180.0 180.0 18.0 TL431AIDBVR SOT-23 DBV 5 3000 202.0 201.0 28.0 TL431AIDBVRG4 SOT-23 DBV 5 3000 180.0 180.0 18.0 TL431AIDBVT SOT-23 DBV 5 250 180.0 180.0 18.0 TL431AIDBVTG4 SOT-23 DBV 5 250 180.0 180.0
in „Analogeingang: Problem bei Überlast“ · Analoge Elektronik und Schaltungstechnik ·
-
PDF
ACclad_H-73247.pdf
AC 121200EM 12 (1/3) ED-M type 12 (0.5) • Excellent dimensional stability (Figure 1) AC 182500EY 18 (1/2) ED-Y type 25 (1) AC 182000EY 18 (1/2) ED-Y type 20(0.8) • Low moisture absorption AC 181200EY 18
-
PDF
Sager_D87P_Service_Manual_Part4.pdf
plane AB18 VSS VSS L15 [5] CLK66_ICH_HUB CLK66 ICH5-2 OC0# D15 OC1# OC0# [20] G21 VCC3_3 VCC1_5 R12 AC2 VSS VSS L21 T180 C10 OC1# D14 OC2# OC1# [20] VCC3_3 VCC1_5 W9 AC4 VSS VSS L23 T178 C9 LAN_RXD0 OC2# C14 R536 100K OC2# [20] E18 ICH5-5 VCC1_5 W10 AC6 VSS VSS M1 T172 C11 LAN_RXD1 OC3# B14 R538 100K
-
PDF
IPB180P04P4.pdf
Final Data Sheet IPB180P04P4L-02 ® OptiMOS -P2 Power-Transistor Product Summary V DS -40 V R 2.4 DS(on),max mW ID -180 A Features PG-TO263-7-3 • P-channel - Logic Level - Enhancement mode • AEC qualified • MSL1 up to 260°C
in „wie pMOSFET für Strombegrenzung kühlen“ · Analoge Elektronik und Schaltungstechnik ·
-
PDF
Mean_Well_EPS-25_Serie.pdf
28.05W 28.08W 28.35W 28.08W 28.32W RIPPLE & NOISE (max.)Note.260mVp-p 60mVp-p 80mVp-p 100mVp-p 100mVp-p 180mVp-p 180mVp-p 200mVp-p 240mVp-p OUTPUT VOLTAGEADJ. RANGE 3.1 ~ 3.6V 4.75 ~ 5.5V 7.13 ~ 8.25V10.8 ~ 13.5V13.5 ~ 16.5V21.6 ~ 27V 24.3 ~ 29.7V 32.4 ~ 39.643.2 ~ 52.8V VOLTAGE TOLERANCE Note.3 2.0% 2.0%
in „Schaltnetzteil zum Laden von 3S / 1100mAh A123 LiFePO4 Akkus“ · Analoge Elektronik und Schaltungstechnik ·