PDF
Schematics.pdf
6 7 8 PGND VISOIN A P0 A GND GND2 R1 P1 1k D1 P1 P PI PC A P0 P1 PTC1 485_A CO1 C2 CU CO3 C4 PP0 PT 100nF 10nF U1 10nF 100nF VCC CLED1 P1 P1 PI U101 GND1 GND2 PI1016 PI PC R2 2k VCC PI U102 VCC VISOIN PI1015 VISOIN CQ3 PI2 PRPL1 PE0XD0 PI U103 RXD A PI1014 PI REPI U104 RE B PI1013 P1 CO PI U105 DE NC
in „RS485 vermute Störsignale, wie entfernen“ · Mikrocontroller und Digitale Elektronik ·
-
Datei
main.c
* <br><br><b>DC2012</b> * <br>Beschreibung * <br><br><b>TM2010</b> * <br>Messverstaerker fuer 4 x PT100 Temperatursensoren * <br><br><b>AD2010</b> * <br>Beschreibung * <br><br><b>VA2010</b> * <br>Beschreibung * <br><br><b>VA2011</b> * <br>Beschreibung * <br><br><b>IU2011</b> * <br>Messverstaerker fuer
in „Atmega644 EEPROM Initialisieren“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
OWON-XDM1041-Handbuch.pdf
3. Set the sensor configuration file. Press the Load softkey, choose KITS90 or Pt100. 4. Set the display. Press the Display softkey to set the display mode of the result. Temp: only the temperature value will be displayed; measure: only the measurement value will be displayed. All:
in „2x Multimeterdefekt“ · Analoge Elektronik und Schaltungstechnik ·
-
PDF
PT1000_-_Schaltungberechnung.pdf
der Messfehler allein durch die Kabellänge etwa 0.25°C (= 0.95Ω/(3,85Ω/K)). Zum Vergleich mit einem PT100: Hier beträgt die Widerstandsänderung pro Kelvin lediglich 0.385Ω. D.h. der Messfehler bei 20m Kabellänge wäre in diesem Fall: 2.5°C(!) Für den Dreileiteranschluss gilt folgendes Ersatzschaltbild:
in „PT1000 - konkrete Schaltung“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
PT1000_-_Schaltungsberechnung_v2.0.pdf
der Messfehler allein durch die Kabellänge etwa 0.25°C (= 0.95Ω/(3,85Ω/K)). Zum Vergleich mit einem PT100: Hier beträgt die Widerstandsänderung pro Kelvin lediglich 0.385Ω. D.h. der Messfehler bei 20m Kabellänge wäre in diesem Fall: 2.5°C(!) Für den Dreileiteranschluss gilt folgendes Ersatzschaltbild:
in „PT1000 - konkrete Schaltung“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
Bavaria_Electric_Katalog_EC_LOG.pdf
enthalten. Die Reglung der Anlage erfolgt über ein im Mediumaustritt befindlichen Temperaturfühler Typ PT 100. Es stehen zwei Temperatursollwerte zur Verfügung. Der Temperatursollwert 1 z.B. 27°C wird an der Steuerung eingestellt und gespeichert. Ein zweiter Temperatursollwert kann ebenso eingestellt und gespeichert
in „Drezahlregelung EC-Motor“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
LOGO-Broschuere.pdf
0–10 V oder 0/4…20 mA Signale Analogfilter gänge und zum Einstellen von Prozesspara AM2 RTD für PT100 oder PT1000 metern (ab Grundgerät 0BA6 einsetzbar, mit automatischer Sensorerkennung unterstützt den Funktionsumfang der Grund- AM2 AQ für 0–10 V oder 0/4…20 mA Signale geräte 0BA6) ■■ Anzeige von
in „Programmierbarer hardwaretrigger/Schnellschaltrelais“ · Mikrocontroller und Digitale Elektronik ·
-
Datei
Flash_EEPROM.txt
Rtd resistance // Simple Linear equation: // At 35 degree Celsius, the equivalent resistance of a PT100 is 113.607 Ohm. Trtd = (Rrtd - 100.0) * (35.0/13.607); } void save (unsigned long addr, unsigned long value) { unsigned long Flash_Status = 0; FEEADR = addr; FEEDAT = value; //*((unsigned long*)0xFFFF051C
in „Speichern und lesen eines internen EEPROMs“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
Datenblatt-METRAHIT-XTRA.pdf
... 90 % — 0,01 % ...100 kHz 1 Hz 0,1 v. MB pro kHz > 2 V ... 5 V OUTDOOR (... % v. MW + ... D) Pt 100 X- TRA – 200,0 ... 0,3 + 159) OUTD. +850,0 C 1000 V C/F Pt 1000 – 150,0 ...0,1 C 9) DC/AC max. 10 s XOUTD. +850,0 C 0,3 + 15 Sinus K – 250,0 ... 1% + 5 K9) (NiCr-Ni)372,0 C 1) Werte <200 Digit
in „Unsicherheit bestimmen: Multimeter mit Datenblatt“ · Analoge Elektronik und Schaltungstechnik ·
-
PDF
3v6.pdf
0.25 0.1 10 62 0.05~0.12 4.8 BZX55C 91PT 91 1 85~96 450 2000 0.1 0.1 10 68 0.05~0.12 4.4 BZX55C 100PT 100 1 94~106 450 5000 0.1 0.1 10 75 0.05~0.12 4.0 BZX55C 110PT 110 1 104~116 600 5000 0.1 0.1 10 82 0.05~0.12 3.6 BZX55C 120PT 120 1 114~117 800 5500 0.1 0.1 10 91 0.05~0.12 3.3 BZX55C 130PT 130 1 124~
in „Falsche Spannung bei Zenerdiode?“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
updated_COUNT7DEC.pdf
P C#C # P10 PP4 PI0 BC847 PT P1100n 47k C4 PT P4100n CR PT P DO D P6065P6 PI2 T32 47k BC847 P6CC PT 100n P6 Title Size Number Revision A4 Date: 03.05.2019 Sheetof File: C:\HFET\..\4AND_Carry_Compare.SchDoDcrawn By: PI P R21 R22 100k 10k PI P1 P3 P YO Y R23 T15 P6 P21 PR0PIPI51 2N7002 R24 T16 100k C6
-
Datei
main_2014_09_29.c
////////////////////////////////////////////////////////////////////// unsigned int channel8=0; //PT100 float channel9=512; //Poti unsigned int channel14=0; unsigned int channel15=0; unsigned int offset; int PWM, PWM_ON; ////////////////////////////////////////////////////////////////////////////////
in „BLDC-Regler mit PIC32“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
PEP_SMART_I-O_Base.pdf
2/6outputs ±10VDC/20mA Screw Terminal Connectors SM-THERM 4inputs R,S,B,J,T,E,K Array2x3and2x7 SM-PT100 4inputs 2,3or4wire MatingCycles 100 ContactResistance <5mΩ Counter/Timer: Max.Amperage 6A SM-COUNT1 1channel 24-bitincrem.encoder OperatingVoltage <250V SM-COUNT2 2channel 16-bitcounter Software Serial
-
PDF
ina128.pdf
Common-Mode Range vs Output Voltage” show 4 the range of linear operation for ±15V, ±5V, and ±2.5V Pt100 supplies. Cu K +5V Cu VO RG INA128 2.5V − ∆V Ref R3 100Ω = Pt100 at 0°C V 300Ω RG INA128 O Ref 2.5V + ∆V SEEBECK ISA COEFFICIENT TYPE MATERIAL (µV/5C) R , R 1 2 E + Chromel 58.5 66.5kΩ − Constantan
in „Probleme Spannungsmessung mit INA 128“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
ads1220.pdf
2013–REVISED AUGUST 2016 www.ti.com This design example discusses the implementation of a 3-wire Pt100 measurement to be used to measure temperatures ranging from –200°C to +850°C as stated in Table 23. The excitation current for the Pt100 is chosen as I = 500 µA, which means a combined current of 1
in „ADS1220 Temperatur SPI“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
ads122c04.pdf
2018 www.ti.com As stated in Table 26, this design example discusses the implementation of a 3-wire Pt100 measurement to be used to measure temperatures ranging from –200°C to +850°C. The excitation current for the Pt100 is chosen as I = 500 µA, which means a combined current of 1 mA is flowing through
in „ads122C04 ADC 24Bit“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
preis2024.pdf
Burster 2302 Milliohmmeter ISO 127,90 6055 Burster 2318 Milliohmmeter ISO 127,90 6056 Burster 4501 Pt100-Simulator ISO 108,59 8091 Burster 4503 PT 100-Simulator ISO 108,59 7741 Burster 4503S MET 400 MET 400-Simulator ISO 108,59 8188 Burster 6401 T DC-Standard ISO 184,60 6057 Burster 6405 T DC-Standard
in „PeakTech 365eff“ · Analoge Elektronik und Schaltungstechnik ·
-
PDF
ISO124P_datasheet.pdf
20-mA loop, Figure 20 provides a solution using the XTR101 and RCV420 devices. A high-performance PT100 resistance temperature detector (RTD) provides the user with an isolated 0- to 5-V representation of the isolated temperature measurement. 1 13 14 10 4-20mA 0.8mA 0.8mA 3 +V = 15V on PWS740 R XTR105 0.01µF S G 4 ISO124 7 16 +V 2 3 1 6 15 RTD 14 15 (PT100) R Z1) 2 RCV420 9 VOUT 10 5, 13 7 RCM 4 8 1kΩ 11 10 0V - 5V 12 2 16 1.6mA –V Gnd –V = –15V S on PWS740 Figure 20. Isolated 4- to 20-mA Instrument Loop (RTD Shown) 9.2.6 Single-Supply Operation of the
in „Schaltungsaufbau Isolierverstärker für Analogsignal mit Texas Instr. ISO124“ · Analoge Elektronik und Schaltungstechnik ·
-
PDF
mirkonet_tmp.pdf
Farnell SMD-UNDEFN/A 4,00MHz +/- 0,5% Ceramic Resonator SMD 1% N/A N/A N/A N/A N/A N/A N/A 1209941 2 PT100 DM-508 LABFACLILITY PT100, GRADE A YES YES 5,350 6,420 12,840 Farnell 2X5MM/TAILSN/A PT100, GRADE A, 0,05%, MAX. 550C +/- 0,05% -50/+550 N/A N/A N/A N/A N/A N/A 1289666 9 RECTIFIEMB2S FAIRCHILD RECTIFIER
in „Komplettverkauf Bauteile, was wert? - Tabelle“ · Markt ·
-
PDF
22SM-29S_Interface_Protocol1.pdf
DP L1 L2 L3 LT IO chs aa 27H -||- -||- -||- -||- -||- -||- -||- -||- -||- -||- -||- chs a) sensor PT100, PT1000 : TU D5-0 : 0 : °C 1 : °F 3FH : no change TS D5-0 : code of temperature sensor see table TS (below) if D5-0=3FH then no change L1 D5-0 : tenths of Ohm of lead resistance L2 D5-0 : units of
in „Checksumme beim MetraHit-Protokoll bilden, wie?“ · Softwareentwicklung ·
-
Datei
maintst.c
12V (Zündung 12V) inaktiv ist. Temperatur: -Temperatur innen und Temperatur außen sollen über zwei PT 100 erfasst werden und ständig aktualisiert auf dem Display ausgegeben werden. (Zusatz: Motortemperatur in Untermenü (mit zwei Tasten bedienbar) anzeigen) -Warnen bei Glatteis Gefahr. Boardspannungsanzeige
in „Multiplexer mit AtMega abfragen“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
ISO124.pdf
0.8mA 0.8mA 3 +VS= 15V on PWS740 RG XTR105 0.01µF 4 16 ISO124 7 +V 2 3 1 6 15 RTD (1) RCV420 14 15 9 (PT100) RZ 2 7 VOUT 10 5, 13 RCM 4 8 0V - 5V 1k 11 10 12 2 16 1.6mA –V Gnd –V = –15V NOTE: (1) R = RTD resistance at minimum measured temperature. S Z on PWS740 FIGURE 7. Isolated 4-20mA Instrument Loop.
in „Optokoppler etc“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
RCV420.pdf
1mA 5 8 4–20mA V+ = 15V on PWS740 RS XTR101 0.01µF R 100 6 16 1 3 4 15 7 2 14 15 1 +V RTD RCV420 (PT100) R2 5, 13 4 9 V 10 12 ISO 122P 7 O 2.5k 11 8 0V–5V 10 2 16 –V Gnd on PWS740 V– = –15V on PWS740 FIGURE 10. Isolated 4-20mA Instrument Loop (RTD shown). ® RCV420 8 10 4–20mA 11 3 +In 3 15 12 R 15 14
in „Frage zu 4-20mA Receiver RCV420“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
P1K0.520.6W.B.010.pdf
measurement. To minimize the error the testing current should be kept low (approximately 1 mA for pt-100). Temperature error ∆t = RI / E; with E = self-heating coefficient in mW/K R = resistance in kΩ, I = measuring current in mA Nominal values: The nominal or rated value of the sensor is the target value
in „PT1000: wie mechanisch anschliessen“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
MAX4194-MAX4197.pdf
signal-conditioning circuits for ther- where G = (1 + 50kΩ / R )Gis the gain of the instrumen- mocouples, PT100s, strain gauges (displacement sen- tation amplifier. 4 sors), piezoresistive transducers (PRTs), flow sensors, X and bioelectrical applications. Figure 7 shows a simpli- Since V AB is directly proportional
in „ADC nicht sauber sinus auf oszi“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
SC17_GENERAL_TEMP_1996_3.pdf
alternative to more expensive options such circumstances it would be impossible to obtain the as Pt100-resistors or thermocouplers. handbook, full pagewidth 3 5 6.5 V 1 8 VS= 8 to 24 V LP2951CM R17 7 2 430 k C1 4 6 R2 R8 R3 1 F 120 8.2 k 360 OP1 R18 C2 NE532 100 k 100 nF R14 R9 R5 15 k BC558B 22 k 3.3
in „Polynom für PTC KTY84-110“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
TEMP1996.PDF
alternative to more expensive options such circumstances it would be impossible to obtain the as Pt100-resistors or thermocouplers. handbook, full pagewidth 3 5 6.5 V 1 8 VS= 8 to 24 V LP2951CM R17 7 2 430 k C1 4 6 R2 R8 R3 1 F 120 8.2 k 360 OP1 R18 C2 NE532 100 k 100 nF R14 R9 R5 15 k BC558B 22 k 3.3
in „Temperatur Sensor KTY“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
SC17_GENERAL_TEMP_1996_3.pdf
alternative to more expensive options such circumstances it would be impossible to obtain the as Pt100-resistors or thermocouplers. handbook, full pagewidth 3 5 6.5 V 1 8 VS= 8 to 24 V LP2951CM R17 7 2 430 k C1 4 6 R2 R8 R3 1 F 120 8.2 k 360 OP1 R18 C2 NE532 100 k 100 nF R14 R9 R5 15 k BC558B 22 k 3.3
in „Spezifikation Temperatursensor“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
SC17_GENERAL_TEMP_1996_3.pdf
alternative to more expensive options such circumstances it would be impossible to obtain the as Pt100-resistors or thermocouplers. handbook, full pagewidth 3 5 6.5 V 1 8 VS= 8 to 24 V LP2951CM R17 7 2 430 k C1 4 6 R2 R8 R3 1 F 120 8.2 k 360 OP1 R18 C2 NE532 100 k 100 nF R14 R9 R5 15 k BC558B 22 k 3.3
in „KTY81-110 ADC WERT -> Temperatur“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
KTY-Philips.pdf
alternative to more expensive options such circumstances it would be impossible to obtain the as Pt100-resistors or thermocouplers. handbook, full pagewidth 3 5 6.5 V 1 8 V = 8 to 24 V S R17 7 LP2951CM 2 430 k C1 4 6 R2 R8 R3 1 F C2 120 8.2 k 360 OP1 R18 100 nF NE532 100 k R14 R5 15 k BC558B R9 3.3
in „Zwischenwerte vom KTY82-210 berechnen“ · Analoge Elektronik und Schaltungstechnik ·
-
PDF
SC17_GENERAL_TEMP_1996_3.pdf
alternative to more expensive options such circumstances it would be impossible to obtain the as Pt100-resistors or thermocouplers. handbook, full pagewidth 3 5 6.5 V 1 8 VS= 8 to 24 V LP2951CM R17 7 2 430 k C1 4 6 R2 R8 R3 1 F 120 8.2 k 360 OP1 R18 C2 NE532 100 k 100 nF R14 R9 R5 15 k BC558B 22 k 3.3
in „Atmega168 ADC - Schwankungen/Beeinflussungen vom Nachbarpin“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
TMP117.pdf
NIST Traceability while only using a fraction of the power of the power O 2 typically needed for a PT100 RTD. The TMP117 F • SMBus™, I C Interface Compatibility simplifies the design effort by removing many of the N I complexities of RTDs such as precision references, 2 Applications matched traces, complicated
in „Präzise Temperaturmessung mit 12Bit-ADC und NTC“ · Mikrocontroller und Digitale Elektronik ·
-
Artikel
Standardbauelemente
, bis 150°C in C Schaltungen R, D PDF KTY84 0,72 nichtlinear(*), bis 300°C in C Schaltungen R PDF Pt100 / Pt1000 ab 3,00 lineare Kennlinie analoge Messschaltungen F C R (*) Verschaltet man den Sensor als Spannungsteiler (Abgriff an den ADC), so erhält man dadurch eine meist ausreichende Linearisierung
Artikel ·
-
PDF
AD7709__3_.pdf
REFIN(+) In this application, the transducer is an RTD (Resistive Tem- 6.25k perature Device), a PT100. The arrangement is a 4-lead RTD REFIN(–) configuration. There are voltage drops across the lead resistances AIN2 RL1 and RL4, but these simply shift the common-mode voltage. IN(+) XTAL1 There is no
in „AD7709, digitaler ground fürs Quarz?“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
LS0208UD06.pdf
temperature control unit D R A E R P Specification Autronic DMS703: O Spectrograph CCD Spect2 P Photometer PT100 . Temperature Control HSC-3 (air-forced temp. control, temp.range from -35°C to +85°C) E Reflectance Standard (Cal.Labsphere ID SRS-99-020 L Lightsource Halogen Lightsource with daylight filter A H
in „The Siemens S65 132x176, 65536 color display with AVR“ · Projekte & Code ·
-
PDF
Siemens_B4110.pdf
Temperatunnessung 7.4.6 Strommessung Netz / Batterie t Q ] .. Mo100 " 000 Netz / Batterie • , '- - . Pt100 " 000 ~ Gerilt laut Skizze anschließen. Zentralschalter in die Position "oe" bringen. Der ,LOW"- Anschluß ( ~ ) sollle im Sinne eines guten Störspannungsabstandes möglichst Nach dem Segmenttest ist
in „Reparaturversuch: Norma Unilap 701 X“ · Analoge Elektronik und Schaltungstechnik ·
-
PDF
Siemens_B4110_TOC.pdf
Temperatunnessung 7.4.6 Strommessung Netz / Batterie t Q ] .. Mo100 " 000 Netz / Batterie • , '- - . Pt100 " 000 ~ Gerilt laut Skizze anschließen. Zentralschalter in die Position "oe" bringen. Der ,LOW"- Anschluß ( ~ ) sollle im Sinne eines guten Störspannungsabstandes möglichst Nach dem Segmenttest ist
in „Reparaturversuch: Norma Unilap 701 X“ · Analoge Elektronik und Schaltungstechnik ·
-
PDF
HFBR-14XX_Optolink.pdf
0.275 -20.0 -13.0 -17.5 -14.0 -11.6 TA = +25 °C, IF= 100 mA dc -19.1 -11.0 100/140 µm Fiber Cable PT100 -15.0 -12.0 -10.0 dBm peak TA = +25 °C, IF= 60mA dc NA = 0.3 16.0 -9.0 -13.5 -10.0 -7.6 TA = +25 °C, IF= 100 mA dc -15.1 -7.0 200 µm HCS Fiber Cable PT200 -10.7 -7.1 -4.7 dBm peak TA = +25 °C, IF=
in „Debuggen bei EMV-Tests“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
Forum.PDF
TX_nEN Intern PU0at3 PI1ur00 164 VCORE BDBUS4 32 It0at6 VCORE BDBUS5 PI1ur02 CO4_ rt BDBUS6 PI1ur03 Pt 100nF1206 BDBUS7 PI1ur04 Transceiver_M 2 M-Bus.SchDoc 38 NUS 5EN CDBUS0/TXD PI1ur08 RX USB5_EN CTL USB GND CDBUS1/RXD PI1ur09 TX USB5_P POU SB0C00 PI1ur00 USB5_N + SB CDBUS2 PI1ur01 - CDBUS3 43 CDBUS4
in „Raspberry Pi Compute Module 3 (Carrier Board)“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
Preisliste_deutsch_0509_2.pdf
und 0(4)..20mA JX3-AO4 10000569 320,00 JX3-Erweiterungsmodul mit: 2 Eingängen für Temperaturfühler Pt100/Pt1000 o.ä. JX3-THI2-RTD 10000570 190,00 JX3-Erweiterungsmodul mit: 2 Eingänge für Temperaturmessung mit Thermoelementen (TC) JX3-THI2-TC 10000611 190,00 Verfügbar JX3-Erweiterungsmodul mit: Frühjahr
in „Siemens Logo“ · Haus & Smart Home ·
-
PDF
SL13A_Datasheet.pdf
sensor: Testo 735 (system accuracy of 0.05ºC) • Reference temperature probe: Testo High accuracy Pt100 probe (0614 0235) For each temperature point 100 measurements were taken usingtheloggingfunctionoftheSL13Achip.TheRFfieldofthe reader has been turned off during the temperature logging. SL13A– 36 Smart
in „SL13A temperatur auslesen Arduino UNO“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
Forum.PDF
TX_nEN Intern PU0at3 PI1ur00 164 VCORE BDBUS4 32 It0at6 VCORE BDBUS5 PI1ur02 CO4_ rt BDBUS6 PI1ur03 Pt 100nF1206 BDBUS7 PI1ur04 Transceiver_M 2 M-Bus.SchDoc 38 NUS 5EN CDBUS0/TXD PI1ur08 RX USB5_EN CTL USB GND CDBUS1/RXD PI1ur09 TX USB5_P POU SB0C00 PI1ur00 USB5_N + SB CDBUS2 PI1ur01 - CDBUS3 43 CDBUS4
in „Raspberry Pi Compute Module 3 (Carrier Board)“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
ad7706.pdf
DRDY for the AD7705. In this case, the transducer is an RTD (Re- GND sistive Temperature Device), a PT100. The arrangement is a 4-lead RTD configuration. There are voltage drops across the DOUT DIN CS SCLK lead resistances RL1 and R L4t these simply shift the common- Figure 22. Pressure Measurement Using
in „ADC7706 - Kommunikationsproblem“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
ADS1211.pdf
DGND 12pF DSYNC SDOUT XIN SDIO XTAL AGND XOUT SCLK DGND DVDD DV DD DGND C 2 12pF DGND FIGURE 39. PT100 Interface. +15V +In 3 15 4–20mA C T RCV420 14 A P REF 2 IN IN 1.0µF –In 13 A N IN REF OUT 1 5 AGND AVDD AVDD AGND VBIAS MODE –15V AGND DVDD CS ADS1210 DRDY C1 DGND 12pF DSYNC SDOUT XIN SDIO XTAL XOUT
in „Hardware SPI vs. BIT BANGING AD Wandler“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
pm2534ocr.pdf
resistance measurements the PM2534 uses a programmable current s o u r c e . For °C measurements a Pt-100 temp. probe (PM9249 e.g.) must be used. The measured analog signals are multiplexed, and via an ADC and a buffer sent to the microprocessor. The digital part has as most important; the microprocessor
in „Pjilips PM2519“ · Markt ·
-
PDF
pm2521ocr.pdf
of the ratio arms of aThomson bridge. The voltage drop isan indication of the temperature of the Pt-100 probe ; (—50°C . +200°C) and i sappliedtotheADC formeasurement. circuit element principles: Thomson bridge: The temperature probe (resistance thermometer) is included in one arm of a ; balanced resistive
in „Pjilips PM2519“ · Markt ·
-
PDF
DA_Martin_Gohlke.pdf
geschaltete Peltier-Elemente gestellt. An verschiedenen Stellen des Boards wurden Temperatursensoren (PT-100) angebracht, von denen einer als Regelsensor f˜r die Temperaturstabilisierung genutzt wird. Die Peltier-Elemente liegen auf einer Aluminiumplatte (90cm £ 60cm £ 4cm), die auf sechs Fu…˜n (POM) { thermisch
in „LLR Experiment“ · Offtopic ·
-
PDF
AD9954__DDS_.pdf
FALL (R1) = 396.4PS RISE(R2) = 464.3PS R1 R2 3 - 7 0 REF2 200mV 500ns M 500PS 20.0GS/S IT 10.0PS/PT –100PS A CH1 708mV Figure18.ComparatorRiseandFallTimeat160MHz Rev. 0 | Page 12 of 36 AD9954 THEORY OF OPERATION COMPONENT BLOCKS DDSCore ClockInput The output frequency (f O of the DDS is a function of
in „DDS-Funktionsgenerator“ · Mikrocontroller und Digitale Elektronik ·
-
PDF
HBM.pdf
aktiven Aufnehmern und von ●●Minimierung der Leitungseinflüsse durch die patentierte Temperaturen mit PT100 erweitere Kreuzerschaltung ●●Trägerfrequenz für höchste Genauigkeit oder ●●Stand-alone-Funktionalität durch Display und Gleichspannung für dynamisches Messen bis 20 kHz Bedienfeld pro Kanal ●●Etabliertes
in „Suche Dehnungsmessstriefen (DMS) mit hoher Schwingbelastung“ · Analoge Elektronik und Schaltungstechnik ·
-
PDF
Baldor_VS1MX_VFD_Manual.pdf
Digital Input 3 Trip - Run 4 C: Remote Down Suitable for PTC Motor Thermistors 5 +10V Output of type PT100 or similar. Trip Level set at 2.5s 6 O: Forward C: Reverse Only operational using E-trip terminal 7 0V function on Digital Input 3 8-4 Customizing Your Application MN762 8.2.3 Modbus Control Mode (
in „Frequenzumformer“ · Analoge Elektronik und Schaltungstechnik ·